Hilti HVU foil capsule PROFIS anchor design software HAS E Zinc HAS E F Gal HAS E R A4 70 HAS HCR rods FTM 2014 indb 60 28 03 14 12 34 PM February 2014 page 61 HV with HA rod adhesive anchor Design process for typical anchor layouts The design values in the tables are obtained from the design method according to ETAG 001 Annex C and Hilti 3 2 4 HIT RE 500 V3 Epoxy Adhesive Anchoring System Table 89 Suggested embedment and edge distance see figure below based on ACI 318 14 Chapter 17 to develop 125 of fy in Grade 60 wall column starter bars in a linear array with bar spacing 18 inches SDC A and B only1 2 3 4 5 6 ƒ c 2 500 psi approved plans and specifications Notify the Engineer of Record and the Building Department of any substitutions for approval to proceed 3 Check for obvious signs of deterioration or damage around the area to be anchored into i e cracks honeycombing and poor quality or spalled concrete or masonry etc or damage to the rebar Notify the Engineer of Record and the In regards to the torque value for adhesive anchors the torque is mainly used to fasten or clamp down the fixture to the base material If you reference the ICC ES Evaluation Report ESR the Hilti Anchor Product Technical Guide and or the Instructions for Use IFU the value listed for the installation torque will be the maximum torque Hilti Inc 7250 Dallas Parkway Suite 1000 Plano TX 75024 1 800 879 8000 www hilti com The following excerpt are pages from the North American Product Technical Guide Volume 2 Anchor Fastening Edition 19 Please refer to the publication in its entirety for

Anchor HIT V Grade 5 8 Anchor size M8 M10 M12 M16 M20 M24 M30 Tensile N rec kN 8 6 13 8 20 0 35 4 56 2 77 1 112 4 Shear V rec kN 5 1 8 6 12 0 22 3 34 9 50 3 80 0 Note For varied embedment depths please contact your local Hilti engineer for furtherHilti HIT RE 500 V3 Anchor Fastening Technical Manual 29 30 Hilti HIT RE 500 V3 Anchor Fastening Technical Manual Title Hilti Malaysia HIT RE Looking at the 2016 product manual Table 24 in Section 3 2 4 3 4 for the HIT RE 500 V3 adhesive gives installation torque values for various diameters of the HAS thread Related webinar Archived Anchor 101 Anchoring Principles amp Design This presentation will Hilti HAS rod specifications Figure 2 Hilti HIS N and HIS RN specifications Table 4 CA rebar installation specifications with Hilti HVU adhesive anchor system Rebar size 10M 15M 20M 25M d o Drill bit diameter1 2 in or mm 9 16 13 16 1 32mm h ef h nom std depth of embed capsule length mm 90 125 170 210 in 3 1 2 5 6 5 8 July 2014 page 89 Hilti H H 200 with H V Basic loading data for a single anchor – with minimum edge distance Design resistance kN uncracked concrete 32 Mpa Anchor size M8 M10 M12 M16 M20 M24 Min edge distance cmin mm 40 50 60 80 100 120

2020 3 24 nbsp 0183 32 We are using hilti hy200 anchor system which asks for a pre torque of 100 ft lbs I know this is a clamping force to clamp down the attachment The question I am struggling to answer is how can you say that applied torque and resulting tension in the bolt and therefore adhesive epoxy is not going into the concrete b Data covered by Hilti Technical Data Effective anchorage depth Anchor size M6 M8 M10 Eff Anchorage depth h ef mm 30 40 60 30 40 70 40 50 80 Anchor size M12 M16 M20 Eff Anchorage depth h ef mm 50 65 100 65 80 120 75 100 efIn regards to the torque value for adhesive anchors the torque is mainly used to fasten or clamp down the fixture to the base material If you reference the ICC ES Evaluation Report ESR the Hilti Anchor Product Technical Guide and or the Instructions for Use IFU the value listed for the installation torque will be the maximum torque SPECIFICATIONS AND CAD DETAILS Help ensure your design is properly documented Anchor And Rebar General notes and CAD details Download PDF DWG Firestop CAD details Download PDF DWG Anchor Channel CAD details Download PDF DWG Hilti Anchor Channel HAC HAC 40 EDGE Lite HAC 50 EDGE Lite HAC 50 EDGE CRFoS U 156 Epoxy Anchoring TOLL FREE 800 892 7224 800 821 7735 LOCAL 816 525 3640 FAX 816 525 4533 D i v i s i o n 5 Epoxy Anchoring Sikadur 174 AnchorFix 1 Modified Acrylic Anchoring Adhesive Description Sikadur AnchorFix 1 is a two component solvent

1 Torque set anchors rely on minimum hole depth and accurate hole diameter Torque set anchors must have initial embedment torque verified by Registered Special Deputy Inspector with a Drilled In Concrete Anchor Certification Torque wrenchesThere are numerous technical specifications that must be considered when using Concrete Drop in Anchors Considerations include diameter and material type internal thread length minimum edge distance and required hole size The Concrete Drop in Anchor is a great fastener option when working with flush mounting applications www hilti com Anchor Systems Injectable Adhesive Anchors Injectable mortar HIT RE 500 SD HIT RE 500 HIT HY 200 R Page 238 239 Torque bar S TB Page 289 Flush Anchors Drop in flush anchor HKD setting tools and stop drill bits Page 290 291 Drop in anchor HKD SR metric HKV Page 292 Epoxy adhesive Installation direction All Key applications and Hilti Inc 7250 Dallas Parkway Suite 1000 Plano TX 75024 1 800 879 8000 www hilti com The following excerpt are pages from the North AmericanAnchor Channel The following sections include details for the various types of anchor channels and T bolts that Hilti has to offer Select the products that meet your needs and download the details in PDF or DWG format

the epoxy and the anchor bolt breaks D L Bond Strength Epoxy to Steel The bond of grout to the steel anchor bolt can be calculated using 1600 psi as the Bond Strength of epoxy to steel This too is also a conservative number To determine the force at theInstallation Torque for HY 200 The installation torque for current application is 150 ft lb This equates to approximately 9000 when using formula P 12 T KD with a K value of 0 2 and D of 1 quot The embedment depth of anchor is only 6 quot and calculates a tension design capacity of 10 270 based upon breakout bond strength is 12 637 see 229 Anchor Systems www hilti com Anchor Systems Injectable Adhesive Anchors Injectable mortar HIT RE 500 SD HIT RE 500 HIT HY 200 R Page 238 239 Anchor rod metric Hilti HIT Z stainless metric Hilti HIT Z R Hammer drill bit TE YD TE CD PageHILTI ADHESIVE POTIONS FOR POST INSTALLED REBAR I am working on the calcs for shear friction in HILTI software and realized there are 2 different adhesives which we can spec for rebar dowels to be post installed into existing structure Hilti HIT HY 200 and HILTI HIT RE 500 Threaded Rod Specification On the Technical Data sheet for HAS and HIT Z Anchor Rods the threaded rod for HAS R 304 316 is listed as quot ASTM A193 Grade 8 M Class1 quot ASTM A193 list 316 as Grade B8M Is there a reason for dropping the quot B quot on this data sheet threaded rod ASTM A193 304 316 B8M 8M 0